INDONESIA TYPE APPROVAL · DJID / KOMDIGI
Indonesia DJID Certification
Move your wireless products into the Indonesian market.
From product scope and testing to application support and local coordination, Glodacert helps manufacturers, brands and testing partners plan a practical route to Indonesia.
Check my product’s DJID requirements ↗Chinese · English · Bahasa Indonesia coordination

Local understanding.
CROSS-BORDER SUPPORT
No language barrier between your team and Indonesia.
Our team coordinates with Indonesian labs and helps you prepare the application and respond to technical questions in Bahasa Indonesia. We also help assess local certificate-holder options based on applicant eligibility.
01 / DOES MY PRODUCT NEED DJID?
Start with the radio features.
Confirm the product scope.
DJID, formerly associated with the SDPPI name, administers Indonesia’s telecommunications equipment certification under KOMDIGI. Radio and telecommunications functions can bring a product within scope; classification, intended use and any exemptions must be checked against the applicable product list, including KM 469/2025. FCC or CE approval does not replace Indonesian certification.
Wi-Fi / RLAN
Routers, access points, laptops, smart TVs and products with 2.4, 5 or 6 GHz wireless connectivity.
Bluetooth & SRD
Wireless mice, keyboards, headsets, speakers, remotes and wearables with short-range radio functions.
Cellular / LTE / 5G
Phones, tablets, modems, CPE and equipment incorporating a cellular radio module.
IoT & smart home
IP cameras, smart plugs, sensors and connected appliances with integrated radio functions.
FREQUENCY PLANNING
Check your bands before you test.
Product configuration matters. Confirm the permitted bands, output power, antenna, equipment category and firmware settings for Indonesia before booking tests. The summaries below are planning references; cellular spectrum authorisation and operator deployment are separate matters.
Wi-Fi / RLAN — 2.4, 5, 6 and 60 GHz
| Band | Frequency range | Planning notes |
|---|---|---|
| 2.4 GHz | 2400–2483.5 MHz | Class-licence technical limits apply |
| 5 GHz (low) | 5150–5250 MHz | Equipment category and indoor restrictions apply |
| 5 GHz (mid) | 5250–5350 MHz | Equipment category and operational restrictions apply |
| 5.8 GHz | 5725–5825 MHz | Check equipment category and power limits |
| 6 GHz | 5925–6425 MHz | LPI / VLP categories; confirm output power and lab scope |
| 60 GHz | 57–64 GHz | Indoor use conditions apply |
5470–5725 MHz is not included in the RLAN band list in KM 12/2025. Review any unsupported channels and the Indonesia firmware configuration before submission.
For 6 GHz, confirm LPI or VLP classification and the laboratory’s recognised 5925–6425 MHz testing scope. Power, installation and operating restrictions apply.
Bluetooth & short-range devices
| Technology | Frequency reference | Next step |
|---|---|---|
| Bluetooth | 2400–2483.5 MHz | Confirm the applicable SRD standard and test modes |
| NFC | 13.56 MHz nominal | Confirm the applicable frequency range and field-strength limits |
| RFID / UWB / LPWAN | Product-dependent | Send the exact bands, bandwidth, power and intended use for assessment |
SRD requirements differ by technology. A frequency used in another market is not automatically permitted in Indonesia.
4G LTE — band planning reference
| Band | Uplink / downlink (MHz) | Mode |
|---|---|---|
| B1 | 1920–1980 / 2110–2170 | FDD |
| B3 | 1710–1785 / 1805–1880 | FDD |
| B5 | 824–849 / 869–894 | FDD |
| B8 | 880–915 / 925–960 | FDD |
| B28 | 703–748 / 758–803 | FDD |
| B40 | 2300–2400 | TDD |
| B41 | 2496–2690 | TDD |
| B31 | 452.5–457.5 / 462.5–467.5 | FDD |
The final band configuration, device category, test standard and spectrum conditions must be checked for the project. Refer to KM 569/2025 and subsequent applicable guidance.
5G NR — band planning reference
| Band | Uplink / downlink (MHz) | Mode |
|---|---|---|
| n1 | 1920–1980 / 2110–2170 | FDD |
| n3 | 1710–1785 / 1805–1880 | FDD |
| n5 | 824–849 / 869–894 | FDD |
| n8 | 880–915 / 925–960 | FDD |
| n28 | 703–748 / 758–803 | FDD |
| n40 | 2300–2400 | TDD |
| n41 | 2496–2690 | TDD |
Confirm the product’s supported modes and applicable technical requirements. Inclusion in a technical standard does not by itself authorise a network deployment or guarantee commercial availability.
02 / WHY PLAN NOW
The requirements keep moving.
Your route should keep up.
Recheck your lab and report before setting a launch date. These milestones explain what changed.
- JANUARY 2025
SDPPI to DJID under KOMDIGI
Telecommunications certification services sit within the Directorate General of Digital Infrastructure. The DJID name appears on current certificate numbers.
- 2025–2026
Product list and cellular standards
KM 469/2025 updates the mandatory product list. KM 569/2025 sets updated LTE and IMT-2020 technical requirements. Check the product category and transition provisions for each project.
- JANUARY 2026
6 GHz RLAN report requirements
KM 12/2025 and Circular B-63/2026 address the domestic or MRA laboratory route and the required 5925–6425 MHz testing scope.
- APRIL 2026
Updated SAR framework
KM 197/2026 updates the SAR framework for relevant phones and tablets. Assess the applicable test configuration and supporting documents for the specific device.
- 2027 PLANNING WATCH
Review non-MRA report eligibility early
Official policy communications have described a move towards MRA-based acceptance of foreign reports from 2027. Confirm the current recognition decision and any new transition notice; do not assume a universal all-local-testing requirement or an automatic extension of a non-MRA route.
Last updated:
03 / PICK YOUR ROUTE
Two routes to assess.
One practical plan for your product.
We check which reports you can reuse, where to test and what fits your launch schedule.
- Check product scope
- Review testing options
- Prepare the application
A / Domestic testing or recognised MRA laboratory
Arrange testing through an eligible Indonesian laboratory or an appropriately recognised foreign laboratory under an applicable MRA.
- Check recognition and the exact technical scope.
- Plan sample quantities, firmware and test modes.
- Confirm report acceptance before testing starts.
B / Designated foreign laboratory report
Where current rules allow, a report from a specifically designated non-MRA foreign laboratory may support a document-based application.
- Check the laboratory, address, product scope and report details.
- Existing reports may reduce repeat testing if accepted.
- Review the 2026/2027 transition and any product-specific restrictions.
A report’s origin alone does not determine acceptance. Neither route guarantees approval; recognition, technical compliance and the authority’s assessment remain essential.
ADDITIONAL REQUIREMENTS
Look beyond the RF report.
Depending on the device, additional evidence may be required alongside the core DJID application.
TKDN / local content
Tingkat Komponen Dalam Negeri documents the local content of a product. Applicability and thresholds depend on the regulated equipment category and current requirements.
Assess this early for cellular products and other equipment subject to Indonesian industrial requirements.
SAR / human RF exposure
Specific Absorption Rate measures RF energy absorbed by the body. Relevant phones and tablets may need SAR compliance evidence under the applicable framework.
Review use positions, test configurations and the required supporting documents before submission.
Typical preparation also includes technical specifications, product photographs, test reports, declarations and applicant or brand-authorisation documents. A module report may require additional integration evidence.
Ask which documents apply to your product ↗LOCAL COORDINATION / GLOBAL EXPERIENCE
Indonesia insights and collaboration.

Published
DJID testing and certification coordination
Read about Glodacert’s exchange with HCT on Indonesia market access, local testing and certification-service cooperation.
Read the Indonesia collaboration story ↗Follow the requirements at source.
Use the official certification portal and regulatory documents to check product scope, recognised laboratories and current application obligations.
View the official reference links ↓FREQUENTLY ASKED QUESTIONS
Plan the next step with clarity.
Does FCC or CE approval replace DJID certification?
No. FCC or CE approval does not replace Indonesian certification. Existing test reports can be reviewed for potential use only if the laboratory, technical scope and current report-acceptance requirements are satisfied.
Does every connected product need DJID certification?
Not automatically. Radio and telecommunications functions can bring a product within scope, but the product classification, intended use and any exemptions must be checked against the applicable mandatory product list.
Can I use an overseas laboratory report?
Possibly. Acceptance depends on the laboratory’s recognition, location and technical scope, the report and current rules. MRA and designated non-MRA routes have different conditions; 6 GHz RLAN has specific requirements.
Do I need an Indonesian applicant or local representative?
The applicant must meet Indonesia’s eligibility and authorisation requirements. Share your importer or distributor arrangement with us so we can assess the suitable applicant and certificate-holder structure.
What should I send for an initial assessment?
Send the datasheet, brand and model, radio bands and power, existing reports, intended use, target launch date and details of any Indonesian importer or distributor.
LET’S PLAN YOUR INDONESIA PROJECT
Start with a DJID eligibility check.
Tell us about your product and target launch. We will review the scope, identify the information needed and discuss a suitable certification route and quotation.
Write in Chinese or English. Our team coordinates the local requirements in Bahasa Indonesia.
Email your product details ↗Your assessment checklist
- Company, contact name and preferred language
- Product datasheet, brand and model
- Wi-Fi, Bluetooth, cellular or other radio features
- Existing FCC, CE or other test reports
- Target launch date in Indonesia
- Importer, distributor or local-representation needs
The email link opens your email application. Attach the relevant documents there; this page does not submit or store your files.
REFERENCE & REVIEW
Official sources for project planning.
Content reviewed: 19 November 2026. Summaries are a starting point for product-specific assessment; the current official rules and recognition status govern the application.
- DJID application requirements and certificate-holder obligations
- KM 469/2025 — mandatory product list
- KM 12/2025 — RLAN frequencies and technical requirements
- DJID guidance on 6 GHz RLAN testing
- KM 197/2026 — official SAR framework update
- Official communication on foreign laboratory recognition and the 2027 policy direction
- DJID certification portal — current regulations, notices and laboratory information