Category: Regulatory Updates

Check out new updates on product certification and IoT labeling schemes

  • Taiwan Expands BSMI Cybersecurity Requirements to Cameras, Routers, Displays and Smart TVs

    Six Product Groups Now Need a Security Test

    Under BSMI Announcement No. 11530018140, effective 2 October 2026, Taiwan now requires cybersecurity testing for network-connected cameras, routers, video recorders, displays and TVs, as well as all concealed cameras. A product counts as network-connected if it uses TCP/IP. The announcement also brings three product types into the regulated scope. Concealed cameras without storage must comply immediately, while cameras without storage and tiled video-wall displays follow on 1 July 2028. Manufacturers already holding certificates for affected products have until 30 June 2028 to reissue them against the new standards, or BSMI will revoke them.

    Which Products Fall Under the New BSMI Cybersecurity Requirements

    The announcement adds a cybersecurity test on top of the existing safety, EMC and RoHS marking checks. Products that are medical devices or telecommunications terminal equipment stay outside the scope, because other laws govern them. For everything else on the list below, the BSMI cybersecurity requirements apply from the announcement date.

    Network Cameras and Concealed Cameras Lead the List

    Digital video cameras with network connection now need a cybersecurity test, whether or not they store footage. Concealed cameras are covered too, with or without a network connection. BSMI defines a concealed camera as a miniature camera built into an everyday item such as a pen, button, pair of glasses, watch or USB drive, with a lens smaller than 2 cm by 2 cm.

    Routers, Gateways and Smart Speakers Join In

    Routers, bridges, switches, network hubs and gateways are now in scope. BSMI explicitly includes smart speakers and smart home assistants in this group. USB hubs and KVM switches remain under simple Declaration of Conformity and need no security test.

    Video Recorders, Displays and Smart TVs Complete the Picture

    On the audio-visual side, network-connected video recorders, displays and TVs must now pass a security standard. Displays and TVs without a network connection keep their current requirements.

    Five Standard Routes to Demonstrate Compliance

    BSMI does not force one standard on everyone. Manufacturers pick one option from a menu, and the menu depends on the product and on how it connects.

    OptionStandard (edition year)Cameras and recordersRouters, displays, TVs
    IoT baselineCNS 16190 (2023)YesYes
    Radio equipment securityCNS 18031-1 and -2 (2025)Wireless onlyWireless only
    Industrial component securityCNS 62443-4-2 (2022)YesYes
    Common CriteriaCNS 15408 parts 1 to 3 (2004) or parts 1 to 5 (2021)YesYes
    Video surveillance seriesCNS 16120 and CNS 16132 seriesYesNot offered

    Wireless Products Choose From the Full Menu

    A product with wireless connection, or with both wireless and wired, may use any option listed for its product group.

    Wired-Only Products Cannot Use CNS 18031

    The CNS 18031 route is reserved for products with a wireless interface. A camera that only connects by Ethernet, for example, must choose CNS 16190, CNS 62443-4-2, CNS 15408 or the CNS 16120 series. Cameras use CNS 16120-2 and CNS 16132-2, while video recorders use the -3 parts of the same series.

    New Products Added to the Regulated Scope

    Three product types are newly regulated, and BSMI already accepts applications for all of them.

    ProductRegulated from
    Concealed cameras without storage2 October 2026
    Digital cameras and video cameras without storage1 July 2028
    Tiled video-wall displays1 July 2028

    Certificates issued before 1 July 2028 start their three-year validity on that date. Concealed cameras must also carry this Chinese warning on the packaging and in the manual: 「嚴禁用於他人非公開活動與身體隱私部位,違者自負刑事與民事責任」. It states that using the device on other people’s private activities or private body parts is prohibited and carries criminal and civil liability.

    Stricter Certification Cybersecurity Schemes

    Product groupNew schemeApplies from
    Network-connected cameras, recorders, displays and TVsTABI, or RPC with a type test plus a quality system or factory inspection module2 October 2026
    Routers, switches, gateways and smart speakersTABI, or RPC with a type test plus a quality system or factory inspection module (replaces Declaration of Conformity)1 July 2028

    Non-connected versions keep the lighter Declaration of Conformity to Type module. Router DoCs signed under the old rules become invalid on 1 July 2028. Unsold stock imported before then needs an RPC certificate or a batch inspection pass before it can be sold.

    Existing Certificates and Test Reports

    Reissue Certificates by 30 June 2028

    Holders of certificates for connected cameras, concealed cameras, recorders, displays and TVs must apply for reissue with proof of compliance to a listed standard. The reissued certificate keeps its original expiry date and will show the standard and security level met. Certificates not reissued in time will be revoked.

    Reuse Old Reports Through Difference Testing

    If an existing IoT or surveillance security report came from a BSMI-recognised lab, that lab can run difference testing against the listed standard and Taiwan’s regional deviations. The updated report is accepted for Type Approval or RPC.

    Transition Timeline for BSMI Cybersecurity Requirements

    DateWhat happens
    2 October 2026New standards apply. Concealed cameras without storage are regulated. BSMI accepts applications for all new products.
    30 June 2028Deadline to reissue existing certificates. Certificates issued under the old rules expire.
    1 July 2028Old standards and schemes end. Cameras without storage and tiled displays are regulated. Router DoCs become invalid. Import control C02 starts for several HS codes.

    Key Takeaways

    • Concealed camera importers have no grace period. Units without storage were regulated on the day the announcement was published. Shipments already in transit may be held at customs without a certificate.
    • Router and smart speaker brands face the steepest climb. Moving from a Declaration of Conformity to full certification with a factory or quality system module adds cost, paperwork and time. Start planning type tests and factory readiness in 2027 at the latest.

    Source: https://www.bsmi.gov.tw/wSite/public/Data/f1790932691717.pdf

  • CRS for AR and VR Glasses: BIS Clarifies How to Register Wearable Glasses in India

    BIS Publishes New Guidance on CRS for AR and VR Glasses

    Smart eyewear is no longer a niche gadget. One frame can now play music, take photos and project information onto the lens. On 13 August 2026, the BIS Registration Department published new guidance Reg/2026/G-01 under the Electronics and Information Technology Goods (Requirement of Compulsory Registration) Order, 2021. It sets out CRS for AR and VR glasses and other wearable eyewear, naming the exact category, sub-category and product name to use. Applicants must now file each product according to its features, and each product name will receive its own licence.

    One Licence per Product Name in CRS for AR and VR Glasses

    BIS will grant a separate licence for each product name listed in the guidance. A brand selling audio glasses, a video-capable smart glasses model and a VR headset will need three licences. Each one has its own application and renewal.

    Wearable Glasses Categories Under CRS for AR and VR Glasses

    BIS sorts glasses by two questions. What can the camera capture, and can the lens display anything?

    ProductCRS CategoryKey Feature
    Audio GlassesWireless Earphones and HeadphonesWireless audio, microphone, speaker, voice assistant. No camera
    Smart GlassesDigital CameraCamera for photos only
    Smart GlassesVideo CameraCamera for photos and videos
    AR Glasses / MR GlassesExtended Reality ProductsOverlay display visible through the lenses
    • Audio Glasses have no camera and no display. Glasses with wireless connectivity, a microphone and a speaker for calls, music and an AI voice assistant go under Wireless Earphones and Headphones.
    • Camera type decides where Smart Glasses go. A camera that takes photos only places the product under Digital Camera. A camera that records both photos and videos places it under Video Camera. The product name stays Smart Glasses in both cases.
    • A lens display makes it an AR or MR product. Glasses with an overlay display visible through the lenses move to Extended Reality Products, registered as AR Glasses or MR Glasses.

    Five Product Names Under Extended Reality Products

    The Extended Reality Products category now has five product names: AR Glasses, Other AR Devices, VR Headset, MR Glasses and Other MR Devices. VR devices are filed as VR Headset. AR and MR devices that are not glasses go under Other AR Devices or Other MR Devices.

    Key Takeaways

    • Classify by features, not by marketing name. Camera type and lens display decide the category. Smart glasses that record video go under Video Camera, not Digital Camera.
    • VR products have one fixed name. Under CRS for AR and VR glasses, VR devices are registered as VR Headset.
    • Plan one licence per product name. Brands with several eyewear models should budget time and cost for each licence separately, and lock features before applying.

    Source: https://www.crsbis.in/BIS/app_srv/tdc/gl/docs/Guidance_on_product_categories_under_Compulsory_Registration_Scheme_(CRS).pdf

  • CNS 61558-1: Taiwan’s BSMI Rolls Out New Standard for Battery Chargers and UPS Devices

    Overview: Battery Charger and UPS Inspection

    On September 8, 2026, Taiwan’s BSMI adopted CNS 61558-1, a new standard harmonized with international IEC 61558-1, replacing the prior domestic basis for testing battery chargers and related electrostatic converters. This conversion path is available for both the battery charger category and the UPS/switching power supply category: manufacturers already holding an IEC 61558-1 (2009 edition) type-test report can redo differential testing to convert it into a valid CNS 61558-1 report, avoiding a full retest. Alongside the standard update, BSMI also expanded which battery chargers require mandatory inspection in the first place.

    CNS 61558-1 Coverage and Scope Expansion

    CNS 61558-1 applies to two distinct product groups under BSMI’s mandatory inspection scheme:

    1. Battery chargers — “other electrostatic converters” category
    This category covers AC-to-DC power adapters. It does not include the steplessly adjustable DC power supply type, and it excludes medical devices and telecom terminal equipment. In simple terms, this is the general-purpose external adapter that plugs into a wall outlet and converts AC mains power to DC. For this category, CNS 61558-1 fully replaces the previous inspection standard. There is no alternative option. Manufacturers with an existing IEC 61558-1 (2009 edition) report can redo differential testing at the originally designated lab to convert it into a CNS 61558-1 report, rather than starting a full type test from scratch.

    This is also where the scope expansion matters most. Non-3C (non-USB) chargers and DC-input chargers were previously outside mandatory inspection. They are now formally brought under CNS 61558-1 testing. This broadens the range of charger types manufacturers need to certify well beyond the standard USB-output charger.

    2. UPS and switching power supplies — “other switching power supplies” category
    This category covers switching-type AC-to-DC power adapters used with uninterruptible power supply systems and similar equipment. It excludes products designed for HI-END audio use, medical devices, and telecom terminal equipment. Here, CNS 61558-1 is offered as an alternative testing route, paired with a second new standard, CNS 61558-2-16. Manufacturers can choose this route or continue using the existing CNS 15598-1 pathway. The same conversion option applies here too: manufacturers holding an IEC 61558-1 (2009 edition) or IEC 61558-2-16 (2009 or 2013 edition) report can redo differential testing to convert it, instead of retesting from zero.

    Unlike the battery charger category, this group is not affected by the non-3C or DC-input scope expansion. The only change here is the added testing option.

    Most other standards in the announcement remain unchanged. These include CNS 15936, CNS 15598-1, CNS 13783-1, CNS 60335-1/2-29, CNS 13803, CNS 14757-2, and CNS 62040-1. RoHS labeling under CNS 15663 §5 also continues as before.

    Supplementary Table: Affected Product Standards

    Category Product Inspection Standard(s) Inspection Method
    Power Supply Equipment Battery chargers CNS 15936 / CNS 15598-1, or CNS 13783-1 / CNS 60335-1 / CNS 60335-2-29; plus CNS 15663 §5 Certification Registration (Type Test mode + Declaration of Conformity mode)
    Power Supply Equipment Wireless chargers CNS 13803; CNS 15598-1; CNS 15663 §5 Type Approval with batch-by-batch inspection, or Certification Registration (Type Test mode + Declaration of Conformity mode)
    Power Supply Equipment Car cigarette-lighter adapters CNS 15936; CNS 15598-1; CNS 15663 §5 Certification Registration (Type Test mode + Declaration of Conformity mode)
    Power Supply Equipment Other electrostatic converters (AC-DC adapters) CNS 61558-1 (new); CNS 15663 §5 Certification Registration (Type Test mode + Declaration of Conformity mode)
    Information Products UPS (≤400A output) CNS 14757-2; CNS 62040-1; CNS 15663 §5 Certification Registration (Type Test mode + Declaration of Conformity mode), or Type Approval with batch-by-batch inspection
    Information Products Electrostatic converters (ADP/peripherals) CNS 15936; CNS 15598-1; CNS 15663 §5 Certification Registration (Type Test mode + Declaration of Conformity mode)
    Information Products Other switching power supplies CNS 15936; CNS 15598-1 or CNS 61558-1 + CNS 61558-2-16 (new); CNS 15663 §5 Certification Registration (Type Test mode + Declaration of Conformity mode)

    Note: Excludes items classified as medical devices or telecom terminal equipment, per each category’s stated exclusions.

    Note: Excludes items classified as medical devices or telecom terminal equipment, per each category’s stated exclusions.

    Transition Timeline for CNS 61558-1 Compliance

    • Now: BSMI accepts certification registration applications under CNS 61558-1.
    • Existing certificates: Valid until expiry, unchanged models included.
    • Through June 30, 2027: Renewals/extensions still allowed under the old standard.
    • From July 1, 2027: All new applications, renewals, and the expanded charger scope require CNS 61558-1 compliance.

    Key Takeaways

    • CNS 61558-1 is the only newly adopted standard, replacing the AC-DC adapter basis and offering an alternative route for select UPS/switching supplies.
    • The IEC 61558-1 (2009 ed.) differential-testing conversion path is available for both battery chargers and UPS/switching supplies — worth checking with clients before committing to fresh CNS 61558-1 testing.
    • Non-3C and DC-input chargers are newly in scope. Clients making these should start planning now, not in 2027.
    • Full CNS 61558-1 compliance is mandatory from July 1, 2027, giving roughly a 10-month runway from this announcement.
    • The 14-working-day review period (plus 7 for sample testing) means early filing avoids a pre-deadline bottleneck.
  • China’s GB 47372-2026: New CCC Power Bank Requirements

    The New CCC Power Bank Standar

    CNCA released Announcement No. 7 of 2026 on May 31, 2026. Through this announcement, the newly finalized national standard GB 47372-2026, “Safety Specification for Power Banks,” became part of the compulsory certification framework covering power banks and their batteries. The standard becomes effective on 1 April 2027, replacing the trial arrangement that certification bodies had followed since power banks and lithium batteries were first brought fully under CCC rules in August 2025.

    This is not a single-document update. A companion set of implementation rules accompanies the new standard, and the two together determine how power banks, battery cells, and battery packs will be tested, categorized, and monitored going forward.

    Scope: Which Products Fall Under the New CCC Power Bank Standard

    The updated framework sorts affected products into three groups, each tied to its own combination of standards:

    • Finished power banks and portable outdoor energy storage units — tested against a bundle of three standards together: GB 4943.1, GB 31241, and GB 47372.
    • Batteries built for phones and other everyday digital devices (excluding e-cigarette batteries) — remain under GB 31241 only, unaffected by the new addition.
    • Cells and packs built specifically to pair with power banks or outdoor storage units — sit in a middle category, tested under both GB 31241 and GB 47372.

    The practical effect of this split is that finished power banks and their purpose-built batteries carry the full burden of the new standard, while batteries intended for general consumer electronics follow a separate and considerably lighter path, covered further below.

    The Highlight of GB 47372-2026

    Rather than adding routine performance checks, GB 47372-2026 targets how products behave under stress. Testing now looks closely at thermal stability when a battery is pushed toward failure and at how protective circuitry responds during abnormal charging or discharging events. These requirements sit on top of the electrical safety and EMC testing that products already undergo under standards like GB 4943.1, rather than replacing them.

    Because of this added layer, applicants filing after the effective date should expect certification bodies to request more granular documentation than before, particularly around cell sourcing and battery management system design, since these design choices directly influence how a product performs under the new abuse-testing criteria.

    Revised Implementation Rules for CCC Power Bank Certification

    The implementation rules paired with GB 47372-2026 carry the designation CNCA-C09-02:2026, superseding the trial version, CNCA-C09-02:2025, that had governed certification since mid-2025. Between the announcement’s release and 31 March 2027, applicants filing new CCC submissions are given a choice: they may proceed under either the outgoing 2025 rules or the incoming 2026 rules, whichever better fits their current testing timeline.

    That flexibility ends once the window closes. Every new CCC application filed from 1 April 2027 forward must be processed exclusively under CNCA-C09-02:2026, together with the full standard set it references, with no option to fall back on the earlier rules.

    Certificate Conversion Deadline and Exceptions

    Companies already holding CCC certificates for complete power banks and their dedicated batteries face a firm cutoff. Before 31 March 2027, they must finish any supplementary testing the new standard requires, pass an on-site factory audit, and migrate each certificate to the new rules. Certificates left unconverted past that point are revoked automatically, with no grace period described in the announcement.

    Manufacturers of batteries for general digital devices are treated differently. Rather than a fixed migration deadline, their certificates carry forward under a natural transition approach, meaning compliance with the new rules only becomes necessary when a certificate comes up for renewal or when the underlying product design changes. This gives that segment of the market considerably more breathing room than power bank and matched-battery certificate holders.

    Key Takeaways

    • Manufacturers of finished power banks and their dedicated matched batteries face a hard deadline: certificates not migrated by 31 March 2027 lapse automatically, so factory audits and supplementary testing should be scheduled well in advance rather than close to the cutoff.
    • The overlapping standard set (GB 4943.1, GB 31241, GB 47372) means certification planning should account for all three simultaneously rather than treating GB 47372-2026 as a standalone addition to existing testing.

    Source: https://www.cnca.gov.cn/zwxx/gg/2026/art/2026/art_f87e199f351c46e59e392a87570d5a74.html

  • Korea’s MEPS Rules for Fans, Dryers, Boilers, Air Fryers, and Printers Explained

    Overview: Two Effective Dates, Not One

    Korea amended its MEPS (Minimum Energy Performance Standards) rules on May 27, 2026, under Notification No. 2026-137, but the new requirements don’t all land on the same day. Gas boilers and clothes dryers move first, with new thresholds taking effect October 1, 2026. Fans, air fryers, and printers follow a few months later, on January 1, 2027. In both cases, what matters is the product’s manufacture date rather than when it’s imported or sold, and that rule applies to imported products just as much as domestic ones.

    Under Korea’s efficiency labeling system, most regulated products carry a 1-to-5 grade label, similar to the energy stickers seen on appliances elsewhere. MEPS sits underneath that system as the minimum bar a product has to clear before it can be sold at all, whether or not it ends up with a grade label. That distinction matters here, since not every product in this update gets a star rating, as the sections below explain.

    Gas Boilers and Clothes Dryers: Effective October 1, 2026

    Residential gas boilers will need to hit a minimum heating efficiency of 93.0% for condensing models and 81.0% for general models, alongside tighter standby power limits of 3.0W and 5.0W respectively.

    Clothes dryers get a maximum power use ceiling of 733 Wh per kilogram of drying capacity. That same number also anchors the bottom of the dryer’s 1-to-5 efficiency grade scale, so it affects both compliance and how a product gets labeled.

    Fans, Air Fryers, and Printers: Effective January 1, 2027

    Fans move to a new formula-based threshold that depends on the motor type, whether induction or DC/BLDC, and the fan guard style, radial mesh or non-radial mesh. This update also brings circulators formally under the fan definition for the first time, closing a gap where they’d previously sat outside the rule entirely.

    Air fryers now need to meet a minimum efficiency of 0.260 kJ/Wh. The test itself is fairly hands-on: it heats a 950g brick to 180°C and measures how much energy that took, within a 60-minute window. Miss that window and the unit fails the standard outright, no matter how efficient it otherwise was.

    Printers are measured against a maximum weekly power consumption limit that scales with both print speed and print technology, whether thermal, dye-sublimation, electrophotographic, thermal transfer, or solid ink. Sleep mode and off mode power draw each get their own separate caps.

    Not All Products Get a Grade Label

    Even though the 1-to-5 grade label applies to most regulated products, fans, gas boilers, air fryers, and inkjet printers are exempted from this rule. These four only need to clear the minimum efficiency floor to be sold, so their label shows a pass or fail against the threshold rather than a star rating. Clothes dryers and non-inkjet printers, by contrast, still get the full 1-to-5 grade treatment.

    What This Means for Manufacturers and Importers

    The compliance path looks the same across all five products: test at a KEA-designated lab, check the result against the threshold, apply whichever label applies (grade or pass/fail), and register the model with KEA before the product ships. None of this touches KC certification, which remains a separate track entirely. Where a product falls under both, it needs both, and passing one never substitutes for the other.

    Key Takeaways

    • Boilers and dryers change first, on October 1, 2026, with fans, air fryers, and printers following on January 1, 2027. Build testing timelines around manufacture date, not shipping date.
    • Air fryers and printers are newly added categories, so for clients selling these into Korea, this is a new compliance step to plan for rather than a retest of something already in place.
    • Fans, gas boilers, air fryers, and inkjet printers only need to clear the minimum threshold. No 1-to-5 grade label applies to these four.
    • Circulators are now officially fans under this rule. Clients making or importing circulators for Korea should treat this as a new obligation starting January 1, 2027.
    • MEPS and KC certification stay separate. A product in scope for both needs both, independently of each other.

    Source

    Korea Energy Agency (KEA) / Ministry of Climate, Energy and Environment (MCEE), Notification No. 2026-137, “효율관리기자재 운용규정” (Operational Regulation on Equipment for Efficiency Management), issued May 27, 2026. https://eep.energy.or.kr/pds/view.aspx?no=201&cate=4